Skip to content

Room documentation for the fitters

When the kitchen is laid out, EFS Web makes a PDF for the fitters and the electrician with one click: the room's floor plan, an elevation of every wall with dimensions, and an installation plan with the mounting heights and the installations. In the installation plan EFS compares the installations you have drawn with the ones the sink, hob, cooker hood, oven, fridge and dishwasher need, and shows in green and red what is in place and what is not.

Video: B07 Room documentation for the fitters

The same workflow in a short silent video with English subtitles.

Watch on YouTube

Before you start

  • The room is switched on (Show room), with its measurements, openings and installations. See Room, openings and installations.
  • The cabinets face their wall. That is how EFS knows which elevation a cabinet goes on (see Walls A, B, C and D and Where the program takes heights and positions from).
  • The worktop has cut-outs for the sink and the hob. EFS takes the axis of the sink and the hob from the cut-outs. See The worktop: cut-outs and the corner joint.
  • The project has a name: the name field in the top bar, or Name in the Web publish section. The name goes into the header of every page and into the file name.
  • The fronts are not hidden. If you hid them with Shift+F, bring them back with the fronts button in the 3D view toolbar.

Workflow in short

The example is the "Horvat kitchen" from the previous chapters: a room with a window and a door, cabinets along two walls, a sink and a hob with cut-outs in the worktop, and a tall fridge unit.

  1. In the top bar, open the Export menu and click Room documentation (PDF).
  2. The browser downloads the file Horvat kitchen_room_documentation.pdf. At the bottom of the screen it says Room documentation exported, pages: N.
  3. Open the PDF. The first page is the floor plan, then the wall elevations, and the last one is the installation plan.
  4. In the installation plan, in the Installations the elements need table, the green rows are in place and the red ones are not. Say the Socket row for the Fridge is red, with not drawn.
  5. Add a socket for the fridge: open Project settings (Ctrl+,, on a Mac Cmd+,), the Room properties section, the Openings and installations box. Click +, choose Socket, set Wall to the fridge's wall, From wall start to the fridge's axis and Height from floor to 2000 mm.
  6. Export again. The fridge row is now green.

The Openings and installations box with a socket selected: Kind Socket, Wall D, From wall start 300 mm, Height from floor 2000 mm, below it the Room documentation (PDF) button

Show me in EFS Web

Export

You export the room documentation in one of three ways:

Where How
The Export menu in the top bar Click Room documentation (PDF).
Project settings → Room properties In the Openings and installations box, below the list, click Room documentation (PDF). The box shows only while Show room is ticked, and the button only once you open the box.
Export → Production package Tick Room documentation (PDF). The PDF goes into the package with the other exports (see The production package and the supplier order).

The Export menu in the top bar, with Room documentation (PDF) at the bottom of the list

What happens:

  1. EFS measures the model and builds the PDF.
  2. The browser downloads the file to its downloads folder. Some browsers first ask where to save it.
  3. At the bottom of the screen it says Room documentation exported, pages: N. The number of pages depends on the project.
  4. Cabinets that have no label yet (E1, E2…) get one and keep it in the project (see Cabinet labels).

If the room is not switched on, there is no file, and the bottom of the screen says Show the room first (Room properties).

The Room properties section with the Openings and installations box open: the list of openings and installations and the Room documentation (PDF) button below the list

On a phone

Tap … (More) in the top bar. Under the Export heading, tap Room documentation (PDF). Depending on the browser, the PDF opens or is saved to your downloads.

Export settings

The export has no options of its own. Everything comes from the project.

What Where it comes from Default
File name The project name, then _room_documentation.pdf. The project name is the Name field in the Web publish section once you have typed it, otherwise the name in the top bar, and without a name Project. Characters a file system does not accept are replaced with _. <project name>_room_documentation.pdf
Name in the page header The same project name, at the top right of every page. For a project without a name it stays empty. project name
Language The interface language (the language menu in the top bar). With the Croatian interface the pages are in Croatian and the file is called …_dokumentacija_prostora.pdf. interface language
Content The room with its corners and pillars, openings and installations, cabinets, worktops with cut-outs. –

Rules:

  • The PDF is A4, landscape. All dimensions are in millimetres.
  • Every export is a new file in the downloads folder. If a file with the same name already exists, the browser usually adds a number to the new one, e.g. (1).

What is on which page

Page Title What it shows When it is there
1 Floor plan The room from above: cabinets, corners and pillars, windows, doors, installations, dimensions along the walls. always
2–5 Wall A · elevation … Wall D · elevation Each wall seen from the room: cabinets, worktop, corners and pillars, openings, installations, dimensions. for every wall with a cabinet, worktop, opening, installation, corner or pillar
last Installation plan Mounting heights, the table of openings, the drawn installations and the installations the cabinets need. If it is long, it continues on the next page. always

Every page has the title at the top left and the project name at the top right. A kitchen along two walls, with a window on the third wall and a door on the fourth, has six pages: the floor plan, four elevations and the installation plan.

The first page of the PDF, Floor plan: the room from above with wall A at the top, light blue cabinets labelled E1, E2…, dashed wall units, the window and door on the walls, red installation symbols and dimension chains outside the room

Tip

Send the installation plan to the electrician and the plumber before they come on site, while the installations can still be moved. Give the fitter the whole PDF: the floor plan and elevations show where each cabinet goes and at what height.

Cabinet labels

On the floor plan and the elevations the cabinets are labelled E1, E2, E3… On a wall elevation the label is followed by the cabinet name, e.g. E2 Sink base 800. That way you can find from the floor plan which cabinet is meant.

  • A cabinet gets its label at the first export and keeps it in the project. Save the project (Ctrl+S, on a Mac Cmd+S) so the labels are kept for next time.
  • A new cabinet gets the next free number. A deleted cabinet's number is not given out again, so the other cabinets keep their labels.
  • Ctrl+Z does not take back labels that were given out.
  • The EFS assistant uses the same labels when it talks about the cabinets.
  • The numbers do not run in order along the wall.
  • An elevation shows at most 18 characters of the name.
  • Cabinets linked in the Relations panel (left, right, above, below) are drawn as one cabinet: one rectangle over all of them, with the label and name of the cabinet in whose field they are entered. So the tall fridge unit, built from three carcasses, is one cabinet, e.g. E9 Fridge. See Relations.

Installation symbols

Symbol Installation
S Socket
400 400 V connection
W Water
D Drain
G Gas

The symbols are red: on the floor plan next to the wall, and on an elevation above the red dot that marks the centre of the installation. The symbols depend on the language of the PDF: in Croatian they are U, 400, V, O and P.

Floor plan

The room seen from above, with Wall A at the top of the page, Wall B on the right, Wall C at the bottom and Wall D on the left.

What How it is drawn
Room A Width × Depth rectangle, in a thick line.
Base and tall units Filled light blue rectangles with the label (E1…) in the middle.
Wall units A grey dashed outline with the label, over the base units.
Corners and pillars Solid grey rectangles, over the cabinets. If it fits, their size (width × depth) is written in white in the middle.
Window A thick blue line on the wall, as wide as the window.
Door A thick brown line on the wall, as wide as the door.
Installations A red symbol (S, 400, W, D, G) next to the wall, where the installation is.
Dimensions along a wall A dimension chain outside the room: the ends of the base and tall units, corners and pillars along that wall, from corner to corner. Only along a wall with base or tall units, a corner or a pillar; wall units are not in the chain.
Overall dimensions The room's Width above wall A, Depth to the right of wall B.

A corner or pillar is drawn over the cabinets. A cabinet that runs into a pillar therefore shows as an overlap on the floor plan.

Wall elevation

Each wall seen from the room, facing the wall. The start of the wall is on the left, as in the Openings and installations box.

What How it is drawn
Wall A rectangle as long as the wall and as high as the room's Height.
Base and tall units Light blue rectangles from the bottom to the top of the carcass, with label and name. Legs are not drawn, so there is an empty strip down to the floor under the cabinet.
Wall units Light grey rectangles with label and name.
Worktop A beige strip, from the bottom to the top edge of the worktop.
Corners and pillars Grey rectangles from floor to ceiling, on the elevation of every wall they touch. Their size is written inside, as on the floor plan (width × depth from Room properties), when it fits.
Window, door A light blue rectangle with the caption Window or Door. The window has a sill height dimension from the floor.
Installations A red dot and the symbol. Each has two dimensions: horizontal from the start of the wall and vertical from the floor.
Lower dimension chain The ends of the base and tall units, corners and pillars, from the start to the end of the wall. Below it, the total length of the wall.
Upper dimension chain The ends of the wall units and openings.
Height chain on the right From floor to ceiling, through all the key heights: bottom of the base unit carcasses, top of the carcass, top edge of the worktop, bottom and top edge of the wall units, top of the tall units.

The elevation shows the wall as you see it from the room: what stands nearer to you covers what is behind it. A cabinet in front of a pillar therefore covers the pillar, and the worktop stands in front of the carcasses.

Example: base units on 100 mm legs, a 720 mm carcass, a 38 mm worktop, wall units from 1430 to 2150 mm, the ceiling at 2600 mm. The height chain on the right then reads 100, 720, 38, 572, 720 and 450 mm.

The elevation of wall A: light blue base units with labels and names, the beige worktop, light grey wall units, a window with its sill dimension, red installation dots with their dimensions, dimension chains below and above and the height chain on the right

A wall elevation with a centre pillar: the grey pillar from floor to ceiling, cabinets to its left and right, and the pillar's edges in the lower dimension chain

Note

A corner cabinet belongs to one wall only, the one it faces. On the other wall's elevation its place stays empty, and in the lower dimension chain it shows as a gap.

Installation plan

The last page. At the top it says: Positions from the start of the wall (facing the wall from the room, the start is on the left), heights from the floor, in mm.

The installation plan: Mounting heights per wall, the Openings table, the Installations drawn in the room table and the Installations the elements need table with green and red rows

Mounting heights

For every wall with cabinets, heights from the floor in mm. A row is printed only if that wall has what it describes.

Row What it is
Base units, top of the carcass The top edge of the highest base unit carcass, measured from the floor (the legs are under the carcass).
Worktop, top The top edge of the worktop along that wall.
Wall units, bottom The bottom edge of the lowest wall unit.
Wall units, top (hanging rail about 20 mm lower) The top edge of the highest wall unit. The hanging rail for the hangers is about 20 mm lower.
Tall units, top The top of the highest tall unit.

If there is no cabinet in the room, instead of the heights it says No elements in the room yet.

Openings

A table of the windows and doors from the Openings and installations box, by wall, and along each wall in order from its start.

Column What it is
Opening Window or Door
Wall A, B, C or D
From wall start To the left edge of the opening
Width, Height Size of the opening
Sill / from floor Height from floor: the window sill, 0 for a door
Note Text from the Note field

The table is not printed if there are no openings.

Installations drawn in the room

All installations from the Openings and installations box: Installation, Wall, From wall start, Height, For and Note.

The For column says which appliance the installation serves, when it is where that appliance needs it (see When an installation is in place). Otherwise it shows —. For example, the water and drain serve the sink, the 400 V connection the hob, and the socket above the worktop nothing.

If no installation is drawn, instead of the table it says None drawn yet…

Installations the elements need

The installations EFS suggests from the cabinets and the worktop cut-outs: Installation, For, Wall, From wall start, Height and In the room.

In the room Row colour What it means
drawn green An installation of that kind is drawn on that wall, where the appliance needs it.
N mm left of this red There is an installation of that kind on that wall, but not in place. The nearest one is N mm towards the start of the wall.
N mm right of this red The same, N mm towards the end of the wall.
N mm above this red An installation of that kind is in place along that wall (at most 150 mm to the left or right), but N mm higher than the appliance needs.
N mm below this red The same, but N mm lower.
not drawn red There is no installation of that kind on that wall.

Below the table it says: The positions follow the elements and the worktop cut-outs; check them against the appliance makers' installation sheets.

If there is no sink, hob, oven, fridge or dishwasher among the cabinets, instead of the table it says No sink, hob, oven, fridge or dishwasher among the elements…

An example table:

Installation For Wall From wall start Height In the room
Water Sink A 1582 500 drawn
Drain Sink A 1582 450 drawn
400 V connection Hob A 2882 500 drawn
Socket Cooker hood A 2882 2150 582 mm left of this
Socket Fridge D 300 2000 not drawn

The socket for the cooker hood is red because the only socket drawn on wall A is the one above the worktop (2300 mm from the start). EFS takes it as the nearest one and reports that it is 582 mm left of the hob axis.

How EFS knows which installations are needed

Appliances

EFS looks for appliances in two places:

  1. Worktop cut-outs. A sink cut-out gives the sink axis, a hob cut-out the hob axis. The axis is the middle of the cut-out. A cut-out that is not drawn on the worktop (e.g. after the worktop was shortened) gives no axis. See The worktop: cut-outs and the corner joint.
  2. Cabinet names. If the name of a cabinet, or of the template it came from, contains one of the words in the table, the cabinet is that appliance, and its axis is the middle of the cabinet. Upper and lower case do not matter. EFS also recognises the appliance names and the names of the built-in templates in every interface language, e.g. the German Geschirrspüler (dishwasher).
Appliance (For column) Recognised by Installations and Height from the floor
Sink a sink cut-out; a name with "sudoper" or "sink" (e.g. Sink base 800) Water 500 mm, Drain 450 mm
Hob a hob cut-out; a name with "kuhanje", "hob" or "cooktop" 400 V connection 500 mm
Cooker hood comes with every hob, on the same axis Socket 2150 mm
Oven a name with "pećnic", "pecnic" or "oven" (Oven, Oven high…) Socket 300 mm
Fridge a name with "hladnjak", "frižider", "frizider" or "fridge" Socket 2000 mm
Dishwasher a name with "perilica" or "dishwasher" Socket 300 mm, Water 400 mm, Drain 400 mm

Rules:

  • The appliance is on the wall of its cabinet or worktop. A worktop belongs to the wall it is nearest to.
  • If there is a sink cut-out on a wall, a cabinet with "sink" in its name on the same wall does not add a second sink. The same applies to the hob.
  • When a name contains the words of two appliances, the longest matching word wins. A cabinet called "Sink and dishwasher" is a dishwasher.
  • Every "perilica" (Croatian for washer) means a dishwasher, even in the name "Perilica rublja" (washing machine).
  • The heights in the table are EFS defaults, not taken from appliance catalogues. Check them against the manufacturer's instructions.
  • No appliance asks for gas. Drawn gas is on the floor plan, the elevation and the table of drawn installations, but not in the comparison.

Tip

The dishwasher space usually has no cabinet, so no installations are suggested for it either. Draw them yourself: Socket, Water and Drain on the wall behind the dishwasher. They will be in the table of drawn installations, with — in the For column.

When an installation is in place

A suggested installation is drawn when there is a drawn installation of the same kind on the same wall:

  • at most 150 mm to the left or right of the suggested position, and
  • at most 300 mm above or below the suggested height.

If there is no such installation, but there is one of the same kind on the wall, EFS takes the one nearest along the wall. If it is more than 150 mm from the suggested position, EFS prints how far left or right it is. If it is in place along the wall and only its height is wrong, EFS prints how far above or below it is, e.g. 400 mm above this.

Watch out

A red row … mm above this or … mm below this means the position along the wall is right, but the height is not. Compare Height in the table with the Height from floor of the drawn installation.

Where the program takes heights and positions from

Nothing is typed in by hand. EFS measures the model at the moment of export:

  • Position along the wall is the distance from the start of the wall, seen from the room. For cabinets EFS measures all their visible boards; for openings and installations it takes From wall start.
  • Heights are from the floor. For cabinets EFS measures the carcass: the legs are not counted, but they raise the carcass. A cabinet on 100 mm legs, 720 mm high, has its carcass from 100 to 820 mm.
  • A wall unit is a cabinet set as upper (Upper / lower cabinet, the U key). Its height comes from the Upper elements height field in the Scene properties section (default 1430 mm). See Wall units, tall units and flaps.
  • A tall unit is a cabinet whose carcass is 1500 mm high or more. The others are base units.
  • The cabinet's wall is the wall the cabinet has its back to: a cabinet with its back to wall A goes on the elevation of wall A, and so on. The cabinet's direction decides, not which wall it is closest to. The R key (Rotate 90°) turns the selected cabinet by 90°, and Turn to view in the Location panel turns it to the view.
  • The worktop is drawn if it was made with Worktop over selected. On the elevation it runs from the bottom to the top edge of the worktop, and its top edge goes into Mounting heights.
  • Corners and pillars come from the Room properties section (Left corner, Right corner, Left pillar, Center pillar, Right pillar). See Corners, pillars and hip roof.
  • The wall's Height on the elevation is the room's Height.

Openings and installations in the PDF

In the Openings and installations box Floor plan Wall elevation Installation plan
Window blue line on the wall Window rectangle, sill height dimension, width in the upper dimension chain Openings table
Door brown line on the wall Door rectangle, width in the upper dimension chain Openings table
Socket, 400 V connection, Water, Drain, Gas red symbol next to the wall red dot with the symbol, dimensions from the start of the wall and from the floor Installations drawn in the room table and the comparison in Installations the elements need
Note – – Note column

What the PDF does not show

  • The hip roof. On the elevation the wall is a rectangle up to the room's Height. If the fitter needs to know about the slope, write it in Note.
  • Kickboard, fillers, end panels and cornice. Cabinets and worktops are drawn. A narrow gap to the wall, where a filler goes, shows in the dimension chain.
  • Fronts hidden with Shift+F. The cabinets are then shallower on the floor plan by the front thickness. Bring the fronts back before export.
  • Electrical circuits and pipe diameters. The plan gives positions and heights. Write the rest in Note.

Note

EFS Web draws corners and pillars on the floor plan and the elevations; the desktop program does not. See Differences from the desktop program.

Common problems and solutions

I can't see the Room documentation (PDF) button in Room properties. The room is not switched on, or the Openings and installations box is closed. Tick Show room and open the box. Or export from the Export menu in the top bar.

The message Show the room first. The room is not switched on. In the Room properties section tick Show room. If you see only the Floor checkbox, untick it first.

A cabinet is on the wrong wall's elevation. The cabinet does not face its wall. Select it, turn it with R and move it back into place.

The corner cabinet is on only one elevation. That is by design: the corner cabinet belongs to the wall it faces. On the other wall a gap is left in the dimension chain.

The sink or hob has no installations in the plan. The worktop has no cut-out, and the cabinet name does not contain a word from the Appliances table. Add a cut-out to the worktop or rename the cabinet, e.g. to "Sink 80".

The socket for the cooker hood is red, but there is a socket on the wall. That is the socket above the worktop. Add a separate socket for the cooker hood on the hob axis, about 2150 mm from the floor.

A row is red, but it shows only a few millimetres. The position along the wall is right; the height differs by more than 300 mm. Correct the installation's Height from floor.

The dishwasher has no installations in the plan. There is no cabinet with "dishwasher" in its name in its place. Draw the socket, water and drain yourself.

Two cabinets are one wide rectangle with one label on the elevation. They are linked in the Relations panel. If they should be separate, clear the On the left, On the right, Above or Below field that holds the neighbour.

A wall has no elevation of its own. That wall has no cabinet, worktop, opening, installation, corner or pillar.

On the floor plan a cabinet and a pillar overlap. The cabinet stands in the pillar or the corner. Move the cabinet or make it narrower.

The file is called Project_room_documentation.pdf, and the header has no name. The project has no name. Type a name in the top bar, or a Name in the Web publish section.

On the floor plan the cabinets are shallower than in the 3D view. The fronts are hidden with Shift+F. Bring them back with the fronts button in the 3D view toolbar and export again.

The browser did not download the file. The browser blocked the download. Allow downloads for app.easyformstudio.com and export again.

Shortcuts in this chapter

Key Action
Ctrl+, (Mac Cmd+,) Open Project settings, e.g. Room properties
Shift+F Hide or show the fronts (bring them back before export)
R Turn the selected cabinet by 90°, so it gets the right wall
U Upper / lower cabinet
Ctrl+S (Mac Cmd+S) Save the project, and with it the cabinet labels

All shortcuts are in the chapter Shortcuts.

Next

Next chapter: A quote for the customer